• MX216
    • Compare
  • ProductPhoto1
  • ProductPhoto2
  • ProductPhoto3
  • ProductPhoto4
  • ProductPhoto5
  • expand
  • Thumbnail1
  • Thumbnail2
  • Thumbnail3
  • Thumbnail3
RadiForce MX216
21.3" Color LCD Monitor
21.3-inch 2 megapixel resolution cost-performance medical monitor with DICOM Part 14 calibration for viewing medical images.
  • Contact EIZO
2 items
 
  • Features
  • Specifications
  • Documents Compatibility
  • Graphics Boards
  • QC Software & Tools Accessories

Making Each Life Visual

 

Display Both Monochrome and Color

Hybrid Gamma PXLThe MX216 is the first MX-Series monitor to include EIZO's Hybrid Gamma PXL function, which automatically distinguishes between monochrome and color images pixel by pixel, creating a hybrid display where each pixel has optimum grayscale. As a result, monochrome images are displayed in the DICOM® Part 14 grayscale, while color images are reproduced corresponding to Gamma 2.2, for improved efficiency when viewing color and monochrome images together.

Display Both Monochrome and Color

 

Visual Assessment

The Kumamoto Chuo Hospital, Japan, have conducted a visual assessment of the Hybrid Gamma PXL function included on the RadiForce monitor. Approximately a 37% improvement was noted when comparing the use of a color monitor with Hybrid Gamma PXL to one without it. In addition, Hybrid Gamma PXL was found to operate equally as well as monochrome monitors with GSDF when displaying monochrome images.
 

See the White Paper "The Advantages of Hybrid Gamma PXL" [PDF]

Visual Assessment


 

 

Space-Saving Design for Clinical Environment

Compared to the previous MX215, the monitor's width, height, and depth are reduced by 3.4 mm, 22.7 mm, and 45.5 mm respectively – a total of 23% less space – saving more workspace for other tasks in clinics and other facilities.

Space Saving1

Space Saving2



 

Evolve Your Image Reading

Work-and-Flow_logo.jpg

As more image modalities become digitalized, radiologists are viewing an increasing amount of information on their screens. EIZO's unique Work-and-Flow technology alleviates the complexity of the imaging workflow with new functions developed with the radiologist in mind. Users can take advantage of Work-and-Flow features with the monitor and bundled RadiCS LE software.


Quick and Easy Focus

The MX216 is compatible with EIZO's Point-and-Focus function. With Point-and-Focus, you can quickly select and focus areas of your concern with just your mouse and keyboard. Change the brightness and grayscale tones of these areas to make viewing images easier.

Point-and-Focus  

See more with animation gif_animation_icon

 

 

Achieve Clarity True to the Source Data

When the pixel aperture ratio is increased to meet long-term brightness stability, a typically unavoidable decline in sharpness occurs. With EIZO's unique Sharpness Recovery technology, the decrease in sharpness (MTF) is restored. This allows you to display an image safely on the monitor that is true to the original source data, even at high brightness levels.

MTF measures numerically how faithfully the panel transfers detail from the original image data for viewing. When Sharpness Recovery is turned on, in the case of a 2 pixel line pair (spatial frequency of 0.926 cycles/mm) the MTF increases by approximately 65%.
 

Sharpness Recovery


Rotate the Monitor According to the Image

After installing the included RadiCS LE quality control software, you can link the Image Rotation Plus function with the monitor's built-in gravity sensor. This enables the screen to automatically switch to either portrait or landscape mode based on the orientation of the monitor.

 

Rotate the Monitor According to the Image


 

Hassle-Free Multi-Monitor Configuration

Using the DisplayPort connection, you can drive several monitors in a daisy chain sequence. This allows you to configure a multi-monitor setup without the complicated hassle of excessive cabling.

A graphics board that supports daisy chain is necessary.
 

Hassle-Free Multi-Monitor Configuration


 

Make the Precise Diagnosis

EIZO carefully measures and sets each grayscale tone to create a monitor compliant with DICOM Part 14. Furthermore, at startup or upon wakeup, the EIZO patented drift correction function quickly stabilizes the brightness level and compensates the brightness fluctuations caused by the ambient temperature and the passage of time, allowing medical images to be faithfully reproduced with stable brightness and grayscale.

Make the Precise Diagnosis

 

 

Manage Effortless Calibration

With the RadiCS LE software (included) and Integrated Front Sensor (IFS) built into the front bezel, you can easily calibrate to DICOM Part 14 without having to mount, run, and remove an external sensor.

Simple calibration using the monitor backlight sensor is also supported.

Manage Effortless Quality Control


 

Versatile Positioning for Improved Operability

EIZO's highly versatile stand offers tilt, swivel and a wide height adjustment range for greater comfort.


 

Warranty with Safety and Trust

EIZO and its authorized distributors offer a five-year limited warranty.

 

 

Our Contribution to SDGs

As part of its sustainability initiatives, EIZO is contributing towards the United Nations' Sustainable Development Goals (SDGs).   SDGs Logo

Supporting a Healthy Life
Starting with our message “Making Each Life Visual”, we aim to support optimal medical care for each and every individual through accurate diagnosis and treatment afforded by our innovative healthcare technologies.
 
SDGs 03SDGs 08
     
Environmentally Conscious
Our healthcare products are designed to promote energy efficiency for reduced power consumption and greenhouse gas emissions, while maintaining the high performance and functionality needed in healthcare. We also implement a responsible after-service recycling system.
 
SDGs 07SDGs 12
Model Variations MX216-BK: with stand, black
Panel  
Type Color (IPS)
Backlight LED
Size 21.3" (54.0 cm)
Native Resolution 1200 x 1600 (3:4 aspect ratio)
Viewable Image Size (H x V) 324.0 x 432.0 mm
Pixel Pitch (H x V) 0.270 x 0.270 mm
Display Colors 10-bit (DisplayPort): 1.07 billion from a palette of 543 billion (13-bit) colors
8-bit: 16.77 million from a palette of 543 billion (13-bit) colors
Viewing Angles (H / V, typical) 178° / 178°
Brightness (typical) 500 cd/m2
Contrast Ratio (typical) 1500:1
Response Time (typical) 20 ms (black-white-black)
Video Signals  
Input Terminals DisplayPort, DVI-D
Output Terminals DisplayPort (daisy chain)
Digital Scanning Frequency (H / V) 31 - 100 kHz / 59 - 61 Hz
USB  
Upstream USB 2.0: Type-B
Downstream USB 2.0: Type-A x 2
Power  
Power Input AC 100 - 240 V: 50 / 60 Hz
Typical Power Consumption 26 W
Maximum Power Consumption 55 W
Power Save Mode 0.6 W or less
Sensor Backlight Sensor, Integrated Front Sensor, Ambient Light Sensor
Features & Functions  
Brightness Stabilization Yes
Digital Uniformity Equalizer Yes
Hybrid Gamma PXL Yes
Work-and-Flow Point-and-Focus
Preset Modes CAL Switch (DICOM, CAL1, CAL2, Custom, sRGB, Text)
OSD Languages English, German, French, Italian, Japanese, Simplified Chinese, Spanish, Swedish, Traditional Chinese
Physical Specifications  
Net Weight 7.6 kg
Net Weight (Without Stand) 4.7 kg
Hole Spacing (VESA Standard) 100 x 100 mm
Certifications & Standards (Please contact EIZO for the latest information.) CE / UKCA (Medical Device), ANSI/AAMI ES60601-1, CAN/CSA-C22.2 No. 60601-1, IEC/EN60601-1, VCCI-B, FCC-B, CAN ICES-3 (B), RCM, RoHS, China RoHS, WEEE, CCC, EAC
FDA 510(k) Clearance for General Radiography
Dedicated Software  
Monitor Quality Control Software RadiCS Supported
Supplied Accessories (May vary by country. Please contact EIZO for details.)  
Signal Cables DisplayPort (3 m)
Others AC power cord (3 m), USB Type-A - USB Type-B cable (3 m), Utility Disk (RadiCS LE, PDF instructions for use, PDF installation manual), instructions for use
Warranty 5 Years
Dimension Drawing PDF

Manuals

Languages

MX216 Installation Manual English 804 KB PDF
MX216 Instructions for Use English 1.33 MB PDF
MX216 Installation Manual German 830 KB PDF
MX216 Instructions for Use German 1.28 MB PDF
MX216 Installation Manual French 868 KB PDF
MX216 Instructions for Use French 1.27 MB PDF
MX216 Installation Manual Russian 834 KB PDF
MX216 Instructions for Use Russian 1.23 MB PDF
MX216 Instructions for Use Italian 1.26 MB PDF
MX216 Instructions for Use Czech 1.18 MB PDF
MX216 Instructions for Use Swedish 1.2 MB PDF
MX216 Installation Manual Chinese-Simplified 1.11 MB PDF
MX216 Instructions for Use Chinese-Simplified 1.89 MB PDF
MX216 Installation Manual Chinese-Traditional 1.13 MB PDF
MX216 Instructions for Use Chinese-Traditional 1.93 MB PDF
MX216 Instructions for Use Arabic 1.17 MB PDF
MX216 Instructions for Use Danish 1.2 MB PDF
MX216 Instructions for Use Dutch 1.21 MB PDF
MX216 Instructions for Use Finnish 1.18 MB PDF
MX216 Instructions for Use Greek 1.21 MB PDF
MX216 Instructions for Use Korean 1.44 MB PDF
MX216 Instructions for Use Norwegian 1.21 MB PDF
MX216 Instructions for Use Polish 1.19 MB PDF
MX216 Instructions for Use Portuguese 1.23 MB PDF
MX216 Instructions for Use Spanish 1.21 MB PDF
MX216 Instructions for Use Turkish 1.17 MB PDF
MX216 Instructions for Use Estonian 1.19 MB PDF
MX216 Instructions for Use Latvian 1.18 MB PDF
MX216 Instructions for Use Lithuanian 1.19 MB PDF
MX216 Instructions for Use Romanian 1.18 MB PDF
MX216 Instructions for Use Slovak 1.19 MB PDF
MX216 Instructions for Use Slovene 1.15 MB PDF
MX216 Instructions for Use Hungarian 1.21 MB PDF
MX216 Instructions for Use Bulgarian 1.2 MB PDF
MX216 Instructions for Use Croatian 1.17 MB PDF

Compatibility

Date Subject
June 27, 2023 Compatibility between RadiForce monitors using DisplayPort daisy chains
November 1, 2022 HP Z2 SFF G9, Z2 Tower G9, Z2 Mini G9 Workstation and FlexScan, RadiForce Compatibility
February 1, 2022 HP Z2 SFF G5, Z2 Tower G5, Z2 G8 Tower Workstation and FlexScan, RadiForce Compatibility
June 24, 2021 Dell Precision 5820 Tower and RadiForce Compatibility
March 11, 2021 HP Z2 Mini G5, Z2 G5 SFF, Z2 Tower G5 Workstation and FlexScan, RadiForce Compatibility
July 30, 2019 Abnormal Display Issue on Microsoft Windows 10 May 2019 Update (1903)
January 23, 2019 A USB signal transmission error may occur between some PCs and EIZO monitors when using EIZO software.
Graphics Boards
MED-XN83

- EIZO original driver and bios
- Daisy chain supported

Graphics Boards
MED-XN63

- EIZO original driver and bios
- Daisy chain supported

Graphics Boards
MED-XN43

- EIZO original driver and bios
- Daisy chain supported

Recommended
Graphics Boards
MED-XN51LP

- EIZO original driver and bios
- Daisy chain supported

Graphics Boards
MED-XN31LP

- EIZO original driver and bios
- Daisy chain supported

Recommended
Graphics Boards
MED-XN72

- EIZO original driver and bios
- Daisy chain supported

Quality Control Software & Tools
RadiCS UX2

- Quality Control Software
- UX2 Calibration Sensor bundled

Quality Control Software & Tools
UX2 Sensor

- Quality Control External Calibration Sensor

Comfort Light for Reading Rooms
RadiLight

- Comfort Light for Reading Rooms

Arms
LA-011-W

35° up tilt and 180° swivel wide adjustment range

Mounting Bracket
VESAMP100

VESA mounting plate for attaching an IP decoding box to certain FlexScan monitors using VOP-01

Panel Protector
RP-915

- Protect against dust and scratches
- Fit between screen and bezel
- Integrated Front Sensor usable

Monitor Cleaning Kit
ScreenCleaner

- Keep your screen free from dust and fingerprints
- Includes pump spray and cloth

 

  • Making Each Life Visual
  • Creating a Comfortable Reading Environment for Doctors
  • Choosing the Ideal Monitor for Teleradiology
  • RX1270 Case Study for Multi-Modality
  • RX1270 Case Study for Mammography
  • EIZO-Sponsored Seminars Supporting Early Detection of Breast Cancer
  • QC Standards for Medical Monitors
prev next